Welcome, visitor! [ Register | Login ]   rss feed
Post a Classified!
«    »

Solar Panel 40 Watt And Lcd Charge Controller New


current price:
£80.00

fixed price (if available):
£80.00

Solar Panel 40 Watt And Lcd Charge Controller New

Here we have 1 12 v pv solar panel and lcd charge controller never used.

i have had the same unit fitted to my caravan for 1 year now and am very please with the charge it gives.

this  cash on collection item

here are the specs

max power 40 watt

optimum power voltage 16.4 volts

optimum operating current 2.8 amps

open circuit voltage 20.7 volts

panel size  820mm  x  540mm

weight  5.4kgs

charge controller specs

- Rated Voltage: 12V / 24V ( Auto Switch )

 - Max solar panel Load Current : 16A - 24A ( Connect 12V battery, Solar Panel Power: 300W.  Connect 24V battery, Solar Panel Power: 600W )

 -Max Input Solar Panel Power: 300W (12V)  / 600W ( 24V)

 - Max battery output Current : 24A

 - Max input voltage: 50V

 - Over-charging Protection :  13.7V; ( X 2 24V )

 - Low Voltage Cut: 10.5V;  ( X 2, 24V )

 - Reconnected Voltage: 12.6 V;  ( X 2, 24V )

 - No Load Loss: ? 30mA

 - Temperature compensation: -3mv/cell, °C recognise and reset

 - Wire area minimum:  4mm²

 - Voltage drop:  <240mv

 - Dimensions:  13.7 x 11 x 4.7cm

 - Storage Temperature:  -30 ~ 70 °C

 - Humidity Requirements:  ? 90% , no condensation

 - Work temperature : -20?C ~ +60?C

 - Colour: Black

 Features:

 - Maintains full voltage in battery

 - Prevents battery from over-charging

 - Prevents battery from over-discharging

 - Prevents battery from supplying electricity to solar panels at night

 - Battery polarity converse-connection protection

 - Solar panel polarity converse-connection protection

 - Auto locking self-protection mode when current exceeds rate of controller

 - Auto locking self-protection mode when short circuit occurs

 - Controller will auto-separate loads from system in the event of battery low voltage

 - Protection against lightning strikes

 - Automatic Temperature Compensation

 - LCD screen displays charge current, discharge current and battery voltage every 5 seconds

 - Continuous count of charge and discharge current battery hours

 - Auto set-up of charge-on/off and load-on/off voltage depending on voltage level of the battery

 - Manual set-up of charge-on/off and load-on/off voltage option

 - CE & RoHS Certification

 USER’S MANUAL   CMP?16A—24A?Solar Charge Controller

 Please read the manual carefully before you use our products!

 Catalogue

 

1.  Security ………………………………….....1

2.  Feature ………………………………………2

3.  System Connection ………………............3

4.  Operation ……………………………….......4

5.  Fix the Breakdown …………………..........6

6.  Accessory Installation …………...............7

7.  Technical data ………………………………8

 

1. Security

The factors referring to body and property security have been considered during designed the products. But incorrect connection will cause to breakdown. For your security, please do everything according to the following regulation.

•Please contact the local agent before installation, which should be guided by professional

•Prevent any liquid from spattering on controller. Do not clean the controller with wet cloth

•Keep children and incapacity person away from controller

•Keep controller away from electrical heater, warmer and other source of heat; avoid controller under Sun.

•Please check the rated voltage of solar panel, battery, and loads before connection. Their rated voltages all should be 12V (or 24V).

•Pay more attention to connect the positive and negative pole among Solar panels, Battery and Loads correctly..

•The diameter of connecting cable could not be smaller, which should be suited to loads.

•The total rated current of solar panel and loads are kept lower than controller’s rated current.

•Tight and good connection among components.

•Connecting wired battery positive and negative poles directly is prohibited.

 

2.Feature

 

CMP (16A-24A) solar charge controller is controlled by CPU, According to the voltage of battery; controller will adjust the charge current and decide if to supply the loads electricity. The following is the detailed performance:

•Generally keep the battery on full voltage condition.

•Prevent the battery from over-charging.

•Prevent the battery from over-discharging.

•Prevent supplying electricity from the battery to solar panels during nights.

•Reverse Polarity Protection for Battery

•Reverse Polarity Protection for Solar panels

•When the current of load exceeds the rated one of controller, the controller will turn into the self-protection state and is automatically locked up, the screen shows “Overload”.

•Short Circuit happens; The Controller will turn into the self-protection state and is locked up, the screen show “Short circuit”.

•Low voltage happens to battery, the controller will automatically separate loads from system. When the voltage of battery goes up, the loads will automatically restart to work.

•Protection from the lightning strike

•When Controller is normally working, the LCD Screen will show New Charging Current (a dash“-”before the numeral), Discharging Current and Voltage of battery every 5 seconds.

•Controller is always counting Charging Current Hours and Discharging Current Hours of the Battery

•When controller start up, according to the voltage level of battery, Controller will self-setup the Charging-off voltage, the Load-off voltage, the Load-on voltage. These datum is tacitly approved under the standard environment temperature 25?.

•According to varies system temperature, the controller will automatically compensate the temperature of the charging voltage.

•Users could setup the Charge-on or off voltage, the load-off voltage, the Load-on voltage, etc, according to their requirements.

•To prevent battery from over discharging, Controller will automatically control the lowest Load-off voltage of the load, which is no less than 10V (as per 12V battery) or 20V (as per 24V battery). If voltage of the battery is less than 10V (or 20V), the button “-” will stop working.

•To recover its defaults, please keep pressing down the button “Menu” for over 5 seconds.

 

3. Connection

 

As form

•Connect “+” and “-” poles of battery with the correct ports on the controller (the third and fourth ports from the left).

•Connect “+” and “-”poles of solar panel with the correct ports on the controller (the first and second ports from the left).

•Connect “+” and “-” poles of load with the correct ports on the controller (the fifth and sixth ports from the left).

 

Attention!

•Correctly connect the electrodes of solar panels, battery and loads!

•Choose the proper cable according to the current of the loads; the diameter could not be smaller. The cable 4m? minimum is suggested!

 

Sketch of Connection

 

4. Operation

 

                    LCD Screen

                      Button is down

•Startup

    SOLAR REGULATOR         OK          Battery xx.xV         Charge xx.xA

 

                                                                  Load xx.xA

•Menu

Battery xx.V

 

Charge xx.xA               MENU                  SOLAR REGULATOR

 

Load xx.xA

 

•Check the system temperature

  SOLAR?REGULATOR        MENU         Temperature xxx?          OK

 

•Check the charging current

     Temperature xxx?       MENU        Charge xxxxxxAh            OK

•Check the discharging current

     Charge xxxxxx Ah             MENU         Load xxxxxx Ah        OK

 

•Check the battery capacitance

     Load xxxxxx Ah           MENU          Battery SOC xxx%        OK

 

•Check the charge-off voltage of battery

     Battery SOC xxx%         MENU          Charge off xx.xV          OK

 

•Setup the Charge off voltage of battery

 

     Charge off xx.xV                             Charge off xx.xV          OK

 

•Check the load-off voltage of loads

     Charge off xx.xV          MENU          Load off xx.xV          OK

 

•Setup the Load-off Voltage of loads

 

     Load off xx.xV                               Load off xx.xV        OK

 

•Check the load-on voltage of loads

     Load off xx.xv            MENU            Load on xx.xv           OK

 

•Setup the load-on voltage of loads

 

      Load on xx.xV                             Load on xx.xV          OK

 

 

•Adjust Charge-off voltage of Battery, Load-off Voltage of loads and Load-on Voltage of loads into the defaults

Press down   MENU    for more than 5 seconds 

 

•Startup for over-loads

       Overload                      Reset          SOLAR REGULATOR        OK

 

•Startup for short circuit

      Short circuit                     Reset           SOLAR REGULATOR       OK

 

5. Fix the breakdown

 

 

•phenomenon?Green light goes out, the loads stops working, and LCD Screen shows      Battery low

  Reason?Low voltage of battery

Solution?Charge up the battery or change the battery

 

•phenomenon?Green light goes out, the loads stops working, and LCD shows      Over load

  Reason?Overload

Solution? Reduce the quantity of loads and then press Button     Reset

 

•Phenomenon?Green light goes out, the loads stops working, and LCD Screen shows      Short circuit

  Reason?Short circuit is happening to loads.

Solution?Disconnecting the malfunction and then press the button     Reset

•Phenomenon?Green LED is light

               Loads are normally working

•Phenomenon?Red LED is light

Battery is charged up rapidly

•Reason?Red LED is flickering

Battery is in constant voltage (or floating) charged up

•Phenomenon?Red LED goes out

  Reason?Charge-off of battery

  Solution?This is the common phenomenon during nights. If it is so during days, please carefully check the connection among Solar panels, Controller and Battery.

 

6. Accessory Installation

 

•Component?Near-distance thermo scope

Installation?Plug the thermo scope into the socket (back side) of controller before running of controller, and then connect batter with the controller. The thermo scope will normally work after one minute. (According to the fourth Chapter-Operation, the environmental temperature of controller will be available).

•Component?Long-distance thermo scope

Such thermo scope is suitable to the following condition—the location of battery is far away from the Controller. (Please show us the length of cable between battery and controller for ordering the proper thermo scope)

Installation?Plug the thermo scope into the socket (back side) of controller before running of controller, and then connect batter with the controller. The thermo scope will normally work after one minute. (According to the fourth Chapter-Operation, the environmental temperature of controller will be available).

7. Technical datum

  

Model CMP24

Rated Voltage 12V?24VAutomatic distinguish Voltage?48V

Loading current Max 16A——24A

Full charge cut  13.7V/12V?×2/24V?×4/48V Recognize tacitly?rest

Low voltage cut  10.5V/12V?×2/24V?×4/48V Recognize tacitly?rest

Reconnected voltage 12.6V/12V?×2/24V?×4/48V

Temperature compensation  -3mv/cell.? Recognize tacitly?rest

No load loss ?30mA

Wire area Min 10m?

Voltage drop ?240mv

 

 

 

 

 

Packing Included

 

1 x 20A Solar Regulator

1 x Thermoscope

1 x Instruction manual

 

 

 


Solar Panel 40 Watt And Lcd Charge Controller New




Posted By:

toz6toz


selston, Nottinghamshire


December 10, 2011 3:55 am